Thank you for visiting our website. Your personal privacy is absolutely respected and protected by the website. To help you understand how the website collects, uses and protects your personal information, be sure to read the website "Privacy Policy". Thank you!
ACCEPT AND PROCEED
RSSRSS

Products

High Voltage Oscilloscope Differential Probe 50MHz
Home  ›   Products  ›  Oscilloscope Probes

High Voltage Oscilloscope Differential Probe 50MHz

DP-50, 50MHz High Voltage Oscilloscope Differential Probe for oscilloscope

 

 facebook
Product ID: DP-50

 DP-50 Differential Probe 50MHz 6500V

 The DP-50 Differential probe provides a safety means for measuring differential voltage to all models of oscilloscope.  The DP-50 coverts the high differential voltage (<=7000 peak) into a low voltage (<=7.0v, with reference to the earth) and display on the oscilloscopes.  The DP-50 is designed to operate with the 1M Ohm impedance oscilloscope. When combine with the 50 Ohm load, the attenuation will be 2 times. We recommend to use Tecpel PL-10 with DP-50 to expand the measuring with Digital multimeter (DMM) to observe more accurate measurement. The accuracy of oscilloscope is 3% and the DMM is less than 1%. Note: If you connect DP-50 to the DMM without Tecpel PL-10 the accuracy will be higher than 10%.

Specifications:

4 Range Attenuator
50MHz Bandwidth
2 Power Sources
6500V High Voltage Input
<6.5V Low Battery Indicator
<5.5V Auto Power Off
Separable Design, Convenient, Durable
MEET IEC1010, UL3111, TUV GS, CAT III 6500V

 

 

Specifications

Differential Voltage DC + pk AC : 6500V
Bandwidth ( 50 Omh load -3dB ) : 50MHz ( x 100 25MHz)
Common Mode Voltage DC + pk AC : 6500V
Common Mode Voltage RMS CAT II : 6500V
Common Mode Voltage RMS CAT IIIl : 6500V
Attenuation ( Switchable ) : X 100, X 200, X 500, X 1000
Input R ( Each input ) : 27M Omh +/-1%
Input C ( Each input ) : 2.5 PF +/- 2% 2
Maximum Operation Voltage (DC + pk AC ) : 
<= +/- 650V at X 100
<= +/- 1300V at X 200
<= +/- 3250V at X 500
<= +/- 6500V at X 1000
Common Mode Rejection Ration ( C M R R ) : 
60 Hz : > 10,000 : 1
100 Hz : > 1,000 : 1
1 MHz : > 300 : 1
Noise ( Into 50 Omh load ) : <= 2 m Vrms
Input Impedance ( between input) : 54 M Omh // 1.25 PF >
Accuracy ( at 20 ~ 30oC 70% RH after 20 minutes ) : <= +/- 2 %
Maximum Output Voltage : <= +/- 6.5 V
Power source : 1. 9V battery 2. External 6V ~ 9V DC

WARNING

1. Do not use DP-50/100 above 6500V ( DC + peak AC ) between ground and the input or 6500V ( DC + peak AC ) between the input lead.
2. Do not operate DP-50/100 in wet or damp condition.
3. Do not operate DP-50/100 in an explosive atmosphere
4. Do not immerse DP-50/100 in liquids.
5. Do not operate DP-50/100 without covers.
6. Please change the battery when the " LOW BATT" LED is lighted. At this time DP-5/100 can operate but not guaranteed the accuracy.

 

Features:

 

4 Range Attenuator
50MHz Bandwidth
2 Power Sources
6500V High Voltage Input
<6.5V Low Battery Indicator
<5.5V Auto Power Off
Separable Design, Convenient, Durable
MEET IEC1010, UL3111, TUV GS, CAT III 6500V

 

 

Certificate:
  • CE

Contact Detail

Contact:Stanley Hwang
Address: 3F., No.12, Lane. 130, MinQuan Road., XinDian Dist., New Taipei City 23141, TAIWAN
TEL:886-2-2218-3111
FAX:台灣-2-2218-3222
Email:tecpelco@gmail.com
URL:http://www.tecpel.com
http://www.tecpel.com.tw
ZIP:23141