LCR Precision Instruments (LCR-200)
Product ID: LCR-200 Measuring Instrument
Measuring instrument is an essential tool of ensuring accuracy of measurement, for transactions by consumers and industry in every day life, such as water meters, taximeters, electricity meters, weighing machines, etc.
Tecpel provides you high quality LCR measuring instruments which are pieces of electronic test equipment used to measure, among other things, the impedance of a component.
Our measuring instrument can be used in various fields because of that our products have wide meter ranges. Besides, our Dual Liquid Crystal Display with LED back lit is a help to use LCR measuring instrument easily. P>
A good LCR measuring instrument has automatic component recognition. In addition, having basic measurement accuracy of 0.1 %is also important.
With advanced technology of measuring instruments , our products will be more preciser and easily-used. The measuring instruments of Tecpel can fit your need.
Please also see our hot products as below: ph meter Measuring Instrument thermometers Multimeter temperature meter Sound Level Meter clamp meter Key Features: Measurement Parameters : Z , Ls , Lp , Cs , Cp , DCR , ESR , D , Q , and (Theta) Test conditions : 100MHz , 120Hz , 1KHz , 10KHz , 100KHz , 200KHz ; 1Vrms , 250mVrms , 50mVrms , 1Vdc(DCR only) DMM Functionalities Dual LCD Display with LED backlit Open / Short calibration Remote binning capability Auto range / range hold selection
Specifications:
LCR200 SPECIFICATIONS:
Test Condition :
Frequency : 100Hz / 120 Hz / 1KHz / 10KHz / 100KHz / 200KHz
Level : : 1Vrms / 250m Vrms / 50m Vrms / 1Vdc (DCR only)
Measurement Parameters : : Z, Ls, Lp, Cs, Cp, DCR, ESR, D, Q and Theta
Basic Accuracy : : 0.1 %
Dual Liquid Crystal Display with LED backlit
Auto Range or Range Hold selection
Open / Short Calibration
RS232C Interface
Primary Parameters Display
Z : AC Impedance
DCR : DC Resistance
Ls : Serial Inductance
Lp : Parallel Inductance
Cs : Serial Capacitance
Cp : Parallel Capacitance
Secondary Parameters Display
(Theta) : Angle Impedance
ESR : Equivalent Series Resistance
D : Dissipation Factor
Q : Quality Factor
Combinations of Display
Serial Mode : Z-Theta, Cs-D, Cs-Q, Cs-ESR, Ls-D, Ls-Q, Ls-ESR
Parallel Mode : Cp-D, Cp-Q, Lp-D, Lp-Q
DMM Functionalities:
DCV, ACV, DCA, ACA, Diode/Continuity Check
Measurement Range
Parameter Range
Z 0.000 Ohm to 500.0 M Ohm
L 0.030 micro H to 9999 H
C 0.003 pF to 80.00 mF
DCR 0.000 Ohm to 500.0 M Ohm
ESR 0.000 Ohm to 9999 Ohm
D 0.000 to 9999
Q 0.000 to 9999
Theta: -180.0 degree to 180.0 degree
V 0.000mV to +/- 600.0 V
I 0.000mA to +/- 2.000 A
DC Voltage Measurement:
Range : 2V, 20V, 200V, and 600V
Resolution : 1mV, 10mV, 100mV,1V
Accuracy : +/-(0.4 %+3Digit)
Input Impedance : 1M Ohm
AC Voltage Measurement ( True RMS ):
Range : 2V, 20V, 200V, and 600V
Resolution : 1mV, 10mV, 100mV, 1V
Accuracy : +/- (0.8%+5Digit) @ 40Hz~1KHz
Input Impedance : 1M Ohm
DC Current Measurement:
Range : 2A, 0.2A, 20mA and 2mA
Resolution : 1mA, 0.1mA, 0.01mA and 1 micro A
Accuracy : ±(0.4%+3Digit)
Input Impedance: 0.1 ohm @ current > 20mA , 10 Ohm @ current< or = 20mA
AC Current Measurement ( True RMS ):
Range : 2A, 0.2A, 20mA and 2mA
Resolution : 1mA, 0.1mA, 0.01mA and 1 micro A
Accuracy : +/- (0.8%+5Digit) @ 40Hz~1KHz
Input Impedance : 0.1 ohm @ current > 20mA , 10 Ohm @ current < or = 20mA
Continuity Check :
Continuity Threshold : 50 Ohm ( Approximately )
Continuity Indicator : Tone Buzzer
Input Protection : 600V ( max )
Diode Test: Test current : 2.5mA ( Typical )
Open circuit voltage : 5.0VDC ( nominal)
Input Protection : 600V ( max )
General:
Temperature : 0 to 40 deg C ( Operating ) -20 to 70 deg C ( Storage )
Reative Humidity : Up to 85%
AC Power : 110V / 220V +/- 10%, 60 / 50 Hz
Dimensions : 300mm x 220mm x 150mm (11.8" x 8.7" x 5.9" ) (DxWxH)
Weight : 4.5kgsStandard Accessories:
(1) TL09C KelvinClip : 1pc
(2) Test leads : 1pc
Optional Accessories:
(3) TL09A SMD test probe
(4) TL09B Component fixture
Features: